Reference

Troubleshooting

Find the message or symptom you see, then follow the steps. If you still need help, see Contact support.

Connection

What you seeWhat to do
ForgeNode Unavailable or Checking ForgeNode…Open ForgeNode on this workstation and check that its badge is ONLINE. Then refresh the workspace.
ForgeNode Health OnlyForgeNode is running but not accepting work from this browser. Check the ForgeNode dashboard for a license or setup message, then open a project and use Retry local ForgeNode access.
Enable local ForgeNode access / Retry local ForgeNode accessChoose it and allow the browser prompt to access apps and services on this device. If you blocked it, allow local network access for loudgears.com in the browser's site settings. See Allow local access.
CLOUD DEGRADED in ForgeNodeCheck the workstation's internet connection.

A lost connection between the browser and ForgeNode does not mean a run failed. Check the run in the Solve Queue before doing anything else.

ForgeNode setup

What you seeWhat to do
SETUP REQUIRED or DEPENDENCIES REQUIREDChoose Install / Repair Dependencies and wait for it to finish.
DEVICE SETUP REQUIRED / DEVICE ATTESTATION REQUIREDRun Install / Repair Dependencies again. It initialises the workstation's identity. License activation is a separate step.
Activate License keeps coming backComplete the activation page in the browser. If you removed this device under Manage your devices, close and reopen ForgeNode before activating again.
This activation link has expiredGo back to ForgeNode and choose Activate License again.
Download unavailable on the download pageYour workspace has no plan that includes ForgeNode. Choose a plan, or ask your administrator.
CUDA / GPU shows GPU routes unavailableThe workstation has no usable NVIDIA GPU. Use CPU Standard, or update the NVIDIA driver and restart ForgeNode.

Restart required after hibernation

ForgeNode's first run on a computer must start from a fresh Windows start-up. That first run proves the workstation's identity to Microsoft Azure Attestation, and Windows cannot give that proof after it resumes from hibernation (S4) until it is restarted.

  • If Windows resumed from hibernation since its last restart and ForgeNode has not yet completed a run on this computer, the installer shows a restart notice when it finishes, and the workspace shows Computer restart required — new analysis blocked or Connected · New analysis blocked · Restart computer before you submit. Restart Windows (Start > Power > Restart), then open ForgeNode again. Shutting down and powering on with Fast Startup is not a substitute for Restart.
  • After the first run has succeeded, hibernation no longer matters: later runs start normally after the workstation resumes.
  • Reinstalling ForgeNode or resetting its local data makes the next run a first run again.

Boot state unverified — new analysis blocked means ForgeNode could not confirm the workstation's start-up state. Restarting Windows usually resolves it.

Starting a run

What you seeWhat to do
Add to FEA queue is disabledCheck that you selected one STEP file, the load case is bound (or the manual override is saved), a route is available, ForgeNode is connected, and your plan has analyses left.
Save or re-save a Fitment snapshotChoose Load vehicle loads again, or save your manual override. Loading geometry alone assigns no load.
A run of an IGES or X_T file failsIGES and X_T import is in beta. Export the wheel as STEP from your CAD system and run it again.
Choose a STEP … fileSTEP, IGES and Parasolid X_T are accepted (IGES and X_T with an up-to-date ForgeNode). Export the wheel to one of these formats.
This ForgeNode cannot load X_T filesUpdate ForgeNode, or export STEP. See Exporting X_T.
This X_T was written by a Parasolid version ForgeNode cannot readExport the wheel again as X_T from a current CAD release, or export STEP.
This ForgeNode accepts STEP onlyUpdate ForgeNode to load IGES, or export the wheel to STEP.
The IGES surfaces do not close into a solidThe surfaces leave gaps larger than 0.1 mm. Export the wheel as a solid IGES or as STEP. See Exporting IGES.
This IGES file contains more than one bodyExport only the wheel, as a single solid.
This IGES export contains … damaged surface(s) that cannot be repairedForgeNode repairs common IGES defects automatically; these surfaces were beyond repair. Export the wheel as STEP.
ForgeNode could not repair the surfaces of this IGES export / could not mesh the surfacesIGES stores many rounded surfaces as approximations. ForgeNode repairs most of them automatically and checks meshing before the analysis; this file was beyond repair. Export the wheel as STEP.
…outside the size of a wheel. Check the units of the export.The IGES declares the wrong length unit. Export it again with the correct unit, or export STEP.
…export X_T, not X_B / …complete Parasolid text (X_T) headerThe file is a binary or truncated Parasolid export. Export text X_T (.x_t) again.
ForgeNode could not read this X_T file / could not convert this X_T fileThe export could not be decoded. Export the wheel again as text X_T, or export STEP.
ForgeNode could not rebuild this X_T as a closed analytic solidThe rebuilt surfaces did not close into one solid that meshes. Export only the wheel as one body, or export STEP.
Geometry files must be … no more than 50 MBSimplify or re-export the model to reduce the file size.
No public load case availableChoose another matching vehicle, or use an approved manual override.

During and after a run

What you seeWhat to do
The geometry check reports several solid bodiesRemove the extra bodies (caps, bolts, reference solids) so the file contains one wheel solid, then choose Replace CAD file.
Run error · retry availableRead the diagnostic, fix the cause if one is given, then choose Retry / continue run. The same file and load snapshot are reused.
Run error · stoppedRead What to do next in the diagnostic. Start a new analysis once the cause is fixed. The credit was released.
A run seems stuckOpen the Solve Queue, select the run, and check the latest stage in the Job Inspector. Keep ForgeNode running.

Viewing results

What you seeWhat to do
Analysis complete · result unavailableDo not run the analysis again. Check or update ForgeNode, then reopen the run. On the project page, try Recover local result.
The 3D view keeps loadingOpen the result on the workstation that ran it, with ForgeNode running. Use Retry original 3D result.
Only the numerical summary is shownYou are on a different computer from the one that ran the analysis. The 3D fields are stored on that workstation.
FEA FAILEDThis is an engineering verdict, not an error. Review the hotspots, safety factor, and load case, then strengthen the design.
Download PDF Packet is disabledReports need a verified result. Wait for verification to finish, or open the result on the workstation that ran it.

Contact support

Open Support from the account menu, or go to Support, and choose New request. From a failed run, Get help with this run in the Job Inspector attaches the run for you. Replies appear on the request and as an unread count in the account menu. If you cannot sign in, email info@loudgears.com.

Include:

  • the project ID and the Operation or job ID (from the Job Inspector);
  • the ForgeNode version (from the dashboard or Download ForgeNode);
  • the exact message and the last stage shown.

Do not send your CAD file unless support asks for it and your organisation allows it.